Refining Systems

Smooth operation of smelting facilities

Crucibles

Electrical safety - a hot topic

The pots in smelting systems in which the metal is melted are operated with various voltages and currents. The supply is often unearthed. In most systems, the pots must be monitored separately to avoid shutting down the whole plant in the event of a fault. The EDS fault location system is an excellent option here. It quickly and automatically locates defective power circuits.

REQUEST ADVICE

Low-voltage distribution boards, feed-in

A safe power supply is the basis for reliable results

The power supply is decisively important when it comes to smelting systems. The medium voltage fed in is transformed down to 400 V in the transformer stations and fed to the system via cable bars or busbars and the low-voltage distribution board and sub-distribution boards. Bender ISOMETER®s or RCMS residual current monitoring systems monitor this and ensure continuous operation. Power quality drives are the perfect solution for monitoring the main and the sub-distribution boards.

REQUEST ADVICE

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Power Quality/Measuring and monitoring relays Product Overviews 2.7 MB EN2022/05/2525.05.2022
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Insulation Fault Location - Planning and Setup Technical article 112.4 KB EN2019/05/1313.05.2019
Electrical Safety in Control and Auxiliary Circuits Technical article 632.6 KB EN2019/05/1313.05.2019
Electrical Safety in a Modern Nickel Smelting Plant Technical article 358.8 KB EN2019/05/1313.05.2019

Products

Insulation monitoring

ISOMETER® iso685…
ISOMETER® iso685…

Insulation monitoring device for inverter applications and large industrial plants

Power Quality

LINETRAXX® PEM353

Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding

System components

AGH150W-4
AGH150…

Extension of the nominal voltage range of ISOMETER® iso685 series to AC 0...1150 V, DC 0...1760 V

AGH204S-4
AGH204S-4

Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V

AGH520S
AGH520S

Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V

AGH675S-7/AGH675S-7MV15
AGH675S-7…

The coupling device AGH675S-7/AGH675S-7MV15 is designed to extend the nominal voltage range of the ISOMETER® IRDH275BM-7 to AC/DC 0…15.5 kV.

AGH676S-4
AGH676S-4

Extension of the nominal voltage range of ISOMETER® iso685.../IR420-D64 series to AC 0...12 kV

Communication

COMTRAXX® CP9xx-I Serie
COMTRAXX® CP9…-I series

Condition monitor with display and an integrated gateway

Powerscout
POWERSCOUT®

Recognising connections – optimising maintenance

Neutral Grounding Resistance (NGR) Monitoring

LINETRAXX® NGRM700

The advanced Neutral Grounding Resistor Monitor for sophisticated applications

Insulation fault location

ISOSCAN® EDS460-D
ISOSCAN® EDS460-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

ISOSCAN® EDS490-D
ISOSCAN® EDS490-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

Insulation monitoring

ISOMETER® iso685…
ISOMETER® iso685…

Insulation monitoring device for inverter applications and large industrial plants

Details

Power Quality

LINETRAXX® PEM353

Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding

Details

System components

AGH150W-4
AGH150…

Extension of the nominal voltage range of ISOMETER® iso685 series to AC 0...1150 V, DC 0...1760 V

Details
AGH204S-4
AGH204S-4

Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V

Details
AGH520S
AGH520S

Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V

Details
AGH675S-7/AGH675S-7MV15
AGH675S-7…

The coupling device AGH675S-7/AGH675S-7MV15 is designed to extend the nominal voltage range of the ISOMETER® IRDH275BM-7 to AC/DC 0…15.5 kV.

Details
AGH676S-4
AGH676S-4

Extension of the nominal voltage range of ISOMETER® iso685.../IR420-D64 series to AC 0...12 kV

Details

Communication

COMTRAXX® CP9xx-I Serie
COMTRAXX® CP9…-I series

Condition monitor with display and an integrated gateway

Details
Powerscout
POWERSCOUT®

Recognising connections – optimising maintenance

Details

Neutral Grounding Resistance (NGR) Monitoring

LINETRAXX® NGRM700

The advanced Neutral Grounding Resistor Monitor for sophisticated applications

Details

Insulation fault location

ISOSCAN® EDS460-D
ISOSCAN® EDS460-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

Details
ISOSCAN® EDS490-D
ISOSCAN® EDS490-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

Details

Standards

EN 61557-8

Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.

EN 61557-9

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems

EN 61557-15

Electrical safety in low voltage distribution systems up to 1000 V ac and 1500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems

DIN EN 50156-1

Elektrische Ausrüstung von Feuerungsanlagen und zugehörige Einrichtungen - Teil 1: Bestimmungen für die Anwendungsplanung und Errichtung

qhy4raey

Do you have any questions?

Please contact us! We are here to help.

TO CONTACT FORM